Digitrax zephyr xtra vs nce power cab manual pdf

The big attention grabber is the statement the unit can run up to 400 locos and supports up to 400 throttles. The digitrax complete train control system brings fun and realism to model railroading. Zephyr xtra is a breath of fresh air in model railroading. It is a combined command stationboosterthrottle all in one box. How to setup jmri, a pr3, a digitrax zephyr xtra and a mac i recently, finally, dove into dcc at home by buying a digitrax zephyr xtra and a digitrax pr3. Apr 06, 20 if you are going to have a really big layout, i would suggest the nce 5 amp power pro system for it. Xtra units to configure a loconet based system for operation. Power cab manuals welcome to the nce information station. Zephyr xtra dcs51 and zephyr dcs50 systems can program soundtraxx tsunami decoders using blast mode programming on the mainline. Digitrax zephyr express dcc starter set mrchq custom.

Electrical operating instructions pennsylvania railroad middle. Anyone have any experience or problems using an nce command stationpower supply with digitrax components such as the pm42 or bdl168s. Provides all of the capability and ease of use that youve heard about in our power pro system at an entry level price. This site is also a distribution point of my dcc presentations in pdf. Ps315 power supply to provide power to run your dcs50. The power supply can be either 5 or 8 amps and should only be volts higher than the desired track voltage. Why shouldnt i buy a nce powercab instead of a zephyr. If more than 3 volts, the unit will enter safe mode and proportionally limit the maximum current. The zephyr is intended for small scale dcc layouts ho or n scale. Decoder test kit zephyr xtra quickstart guide zephyr xtra manual digitrax decoder manual zephyr xtra offers.

The features of the dt500 add so much to the operational capabilities of the dcs210 that the components should be purchased as a set. Nce manufacturer of dcc electronics for model railroading. Because the power to the rails is always on dcc can provide. Lt1 decoder and loconet cable tester zephyr manual digitrax decoder manual 3. The 5 amp power booster is the most common and the 8 amp power booster should be reserved for g and o scale. Dcs51 allinone throttlecommand stationbooster to run your layout. The digitrax bdl168 manual rrcirkits locobufferusb manual digitrax tech support depot some members of the nce and jmri user groups on. It offers simplified advanced train operation for any size layout.

Introduction to digital command control boulder model railroad. Digitrax zephyr xtra manual pdf download manualslib. Note that the power cab with smart booster setup can only handle a total of 4 throttles, numbers 2345. Ive tried both the nce power cab and digitrax dt400 throttles.

This manual covers the installation and operation of the nce power cabtm dcc. This zephyr xtra set is an improved version of the original zephyr starter set. The loco section is well worth a visit with a good choice at competetive prices and a variety of rolling stock too. Question about digitrax zephyr dcs 50 g scale central. Digitrax zephyr xtra digital command control dcc system. Yes, the power cab will handle it just fine, michael. Psx are not compatible with digitrax analog address 00 or any method that adjusts.

Part of the attraction of the power cab is that it has nearly all of the features youd get with a larger powerhouse pro system for a fraction of the cost. Zephyr xtra gives you simple to use digitrax complete train control for a great price. Unfollow digitrax zephyr to stop getting updates on your ebay feed. Digitrax dcs 52 zephyr express command control starter set. Digitrax zephyr xtra manuals manuals and user guides for digitrax zephyr xtra. Because the zephyr xtra is rated at 3 amps and the zephyr is rated at 2. Features excellent speed control, prototypical consisting, a full range of programming and more. However, you should try both systems power cab and zephyr to determine which one will best fit your needs and preferences. This video will take you though the set up and use of a nce power cab. The two wiring methods shown and described were built and tested by the author, and work for him. Zephyr xtra power supply not sold separately specification sheet. Factory direct trains model trains, railroad accessories. Dcc hobby supply, dcc, digitrax, tcs, nce, soundtraxx, qsi, decoders, zephyr, super chief, blackstone models, bli blueline. In this episode of mr101 we take a look at both nce and digitrax, and try.

The nce power cab and bachmann ez should use a value of 01. Use zephyr express as an expansion set with digitrax equipment you already have installed. Digitrax zephyr express dcc starter set mrchq custom light. Review of the nce power cab dcc train controller system. You can also install additional dcc controlled lighting such as cab lights, mars. I operate digitraxcontrolled layouts not having fun and i own the nce power cab which i find easy to operate. An upgraded version of the zepyhr set introduced several years ago, the digitrax zephyr xtra 3. Perfect for beginners, intermediate and advanced modelers, the easytouse set has everything you need to get started in command control. Anyone have any experience or problems using an nce command station power supply with digitrax components such as the pm42 or bdl168s. Always recommended the existing p515 as the alternative. Zephyr xtra has many more exciting features than other comparably priced control systems.

Education about digital command control dcc used in model railroads to run trains. Since the dcs51 zephyr xtra and dcs50 zephyr are equipped with loconet, adding additional boosters is easy. Either system would handle what you currently want to do. At the same time, i would also get the nce power cab system and use it at the. The power cab is marketed as a starter system, and it is competitively priced with other basic systems on the market. The digitrax zephyr has the jumper ports that are pretty cool. I operate digitrax controlled layouts not having fun and i own the nce power cab which i find easy to operate. Using dc the loco receives its instructions on how fast to run. So ive just about convinced myself the goto starter for a dccathome is the basic nce powercab, i need a second opinion on why the digitrax zephyr is better or equal in case im missing something. I was completely new at dcc and for the price i thought it was reasonable. Digitrax reports that it developed the evolution starter set for new dcc users, as an upgrade path from their zephyr extra set, or as a replacement for older dcs100200 units. Nce power cab 2 cvp products 99 base unit knob 9999. Try them all if you can and download the manuals and flip through them.

Performing factory decoder reset using digitrax zephyr xtra dcs51 or zephyr dcs50overview. Digitrax dh126d ho scale decoder, economy wired install. Digitrax evo evolution advanced 5a8a starter set fdt low price. So, even if you dont have a loco with a decoder, you can still hook. At the same time, i would also get the nce power cab system and use it at the bench for programming and testing locomotives. After researching the different starter dcc control systems, i chose the digitrax. Digitrax dcc hints and tips updated for 20 tonys train. It is a combined command stationboosterthrottle all in.

Ive had a number of decodered locomotives for the significant amount of time i spend visiting or on ntrak layouts, so i was familiar with the basic concepts, but had never got it. Just plugin a ur90, or ur92 receiver and add ir andor radio throttles. Lenz, mrc 30x31x series and digitrax 120 series decoders can not be used with. For me, the power cab was much more userfriendly and intuitive. The zephyr xtra starter set from digitrax is a great way to get started with dcc. Set includes allinone throttlecommand stationbooster, power supply, loconet cable and decoder test kit plus a quickstart guide and instruction manuals. The dcc puts digital control information into the electrical power of the train. To stop the locomotive, either turn the throttle knob back to stop, or shift the.

If you are going to have a really big layout, i would suggest the nce 5 amp power pro system for it. Ready to ship appears directly below its add to cart button. Another big change introduced with the dcs240 is the requirement for a directcurrent dconly power supply. Designed to grow with your layout, the costeffective zephyr express includes the dcs52 command station, ps314 power supply, lt1 decoder tester and loconet cable, system reference manual and decoder manual. The only thing that bothers me is that the nce uses pushbuttons on the main powercab instead of a rotary dial. Programming the digitrax zephyr system addressing using the digitrax zephyr system short address changes to change the k4s address on the zephyr system youll need to use ops mode. I have no idea what the nce user on amazon was doing. Ps314 power supply to provide power to run your dcs51. Our wide choice of dcc decoders is complemented by our stocks of uk locomotives to put them in. Nce cat5 cab bus details welcome to the nce information. Ps314 power supply to provide power to run your dcs52. Off the cuff digital command control dcc comparison.

The digitrax zephyr express dcc starter set offers simplified advanced train operation for any size layout and is fully expandable. Zephyr xtra is perfect for beginning, intermediate and advanced model railroaders. Digitrax zephyr xtra adding dc power pack as additional throttle 2. How to setup jmri, a pr3, a digitrax zephyr xtra and a mac. We have locos from bachmann, dapol, graham farish, heljan and hornby in gauges from n to o. Nce power cab users must do one not both of the following. Px1082 power xtender for use with digitrax decoders equipped with 2 pin px socket or solder pad connections. The digitrax loconet system incorporates many technologies, including dcc, to give you a system that seamlessly handles all aspects of layout control and model train operation. Zephyr from digitrax this is a small step up in cost.

It isnt often that a dcc manufacturer releases a new command station, so the new digitrax dcs240 has drawn interest. Kb33 programming soundtraxx tsunami decoders with digitrax zephyr. The zephyr xtra is a very good system, too, and it has its pluses. Zephyr xtra keeps it simple and still has features real model railroaders want. Digital command control dcc is an exciting field in model railroading that uses digital computer technology to operate model railroad trains.

Series first, then if your trains start to slow down you may need to add extra. I thought about the power cab but its easier for me to run multiple throttles with the zephyr. Make sure that there are no shorts or frayed wires between the. And, you can also use the power cab s throttle on the power pro system as another throttle. And, you can also use the power cabs throttle on the power pro system as another throttle. Digitrax zepher xtra dcc starter set white rose hobbies. Digital command control can seem intimidating, making some novices reluctant to make the switch from directcurrent power packs. Dc and dcc operation of atlas gold series diesel locomotives. Output voltage of the zephyr xtra is fixed at about to 14 volts. Use zephyr express as a starting point for your digitrax loconet system, then add components. Although my layout is small the zephyr has many options, can program decoders, controsl multiple trains including one without a decoder at the same time and is expandable.

This 2 amp system can operate up to 4 ho locomotives or 8 n scale locomotives. Blast mode programming will program everything sitting on the main line track so, you must remove everything from the track that you are not programming or use an isolated piece of. It is recommended that this procedure be performed on the dedicated service mode programming track using direct mode programming. Review may include provided, borrowed or discounted product. Db210opto single 358 amp autoreversing dcc booster that is optoisolated for layouts with common rail wiring. After all, their dcs100 and dcs200 command stations have been around for 20 and 16 years, respectively. We have 1 digitrax zephyr xtra manual available for free pdf download. If this indicator is not lit track power is turned off or the booster is short circuited. The zephyr is a very flexible system and has an output rating of 2. So, if you want to change the short address thats very simply done by. The zephyr is a stationary dcc system that has a network connection. I and all in the club who use the nce throttles much prefer the ergonomics of them over the digitrax ones.

When you are ready to end your session on the layout, you can make the dcs51 remember the settings of switches 1 to 512 in nonvolatile memory by pressing the power key to turn off the track power before turning off the power input into the dcs51. What is the recommended max cab bus length using cat5e cable. All is normal at dallas model works we have a unique setup but some of our suppliers have been slowed down by the covid19 pandemic, which can affect the arrival of some nonready to ship items slightly. Has anyone had a problem converting from the old reohstat dial to this. I bought a zephyr back in august to get back into the hobby.

1363 1367 1425 1536 479 1306 542 70 306 1242 1394 124 719 1356 1270 1537 741 436 1530 40 197 1110 1370 913 646 504 1003